Contact

312.912.1961
sales@gosuma.com

top

Gastight ceiling lead through GDD

For a gas tightness of nearly 100 % on tanks with concrete roof

More details and information about the Gastight ceiling lead through GDD

Technical data

  • For biogas tanks up to 53 ft with concrete ceiling or other load bearing structures
  • Innovative gas tight rope lead through
  • Unique cable guidance behind the mast with cable clips and strain relief
  • Lateral adjustment 360°
  • Service Box:
    • Sealing plate 73.6 x 42 x 0.12 in in stainless 316
    • Guide mast: 4" x 4" (100 x 100 mm) or 6" x 6" (150 x 150 mm); When sourcing the mast locally the suspension system must be adjusted by SUMA – contact SUMA for more details
  • Maintenance unit (optional):
    • Base frame 79.9 x 48.4 x 0.12 in in stainless 316
    • Maintenance cover to close the tank during service and maintenance work
    • Height indication: for indication of the exact agitator height in the tank

More product information

Application:
The gas tight ceiling lead through was developed by SUMA with guaranteed serviceability and optimized for biogas tanks with concrete cover or big lagoons with a concrete bridge.

Adjustment:
The easy adjustment of the horizontal rotation direction is a unique advantage of the GDD.

Gas proof design:
The design of the rope lead through and the service box ensures nearly 100% gas proof operation.

Easy maintenance:
The service box of the GDD simplifies the maintenance of the propeller of the submerged mixer without having to shut down the plant. A special highlight is the optionally available access cover which closes automatically when hoisting the agitator for maintenance. This mechanism reduces the loss of gas while maintenance is in progress. The maintenance unit can be adapted according to the tank ceiling opening.

Long service life:
The GDD is manufactured completely in stainless 316 and is suitable for guide masts 4" x 4" (100 x 100 mm) and 6" x 6" (150 x 150 mm)

Monitoring:
A viewing glass and the height indicator, both standard features, simplify monitoring and adjustment of the submerged agitator.

Application example

Closed Tank

Gasdichte Deckendurchfuehrung GDD für Tauchmotor Gasdichte Deckendurchfuehrung GDD für Tauchmotor

Tank concrete Top

Gasdichte Deckendurchfuehrung GDD für Tauchmotor Gasdichte Deckendurchfuehrung GDD für Tauchmotor Gasdichte Deckendurchfuehrung GDD für Tauchmotor Gasdichte Deckendurchfuehrung GDD für Tauchmotor

Steel Tank

Closed Lagoon

Gasdichte Deckendurchfuehrung GDD für Tauchmotor Lagune

Suitable for following tanks

Closed Tank Tank concrete Top Steel Tank Closed Lagoon

Suitable for

Industry
Biogas